40 Troubleshooting
Failure code [DA26KP] 5V sensor 2 power abnormality
User code
Failure code
—
DA26KP
Contents of
• Voltage of 5V sensor power supply output 2 circuit is below 2.5 V or above 6.0 V.
trouble
Action of
• Turns output of 5V sensor power supply output 2 OFF.
controller
• Even if cause of failure disappears, system does not reset itself until starting switch is turned OFF.
Problem that
appears on
machine
Related
• Method of reproducing failure code: Turn starting switch ON.
information
Ground fault in wiring har-
1
ness (Short circuit with GND
circuit)
Possible causes
and standard
value in normal
Hot short (Short circuit with
state
2
24V circuit) in wiring harness
3 Defective pump controller
Circuit diagram related
PC138US, USLC-8
5V sensor power supply output 2 abnormality
Trouble
(Pump controller system)
Cause
Standard value in normal state/Remarks on troubleshooting
a Prepare with starting switch OFF, then carry out troubleshoot-
Wiring harness between C01 (female) (8) –
A08 (female) (3) (6)
a Prepare with starting switch OFF, then turn starting switch ON
Wiring harness between C01 (female) (8) –
A08 (female) (3) (6)
If causes 1 – 2 are not detected, pump controller may be defective.
(Since trouble is in system, troubleshooting cannot be carried out.)
ing without turning starting switch ON.
and carry out troubleshooting.
SEN02464-01
1
Resis-
Min. 1 Mz
tance
Voltage
Max. 1 V
43