5. Function Menu Screen Display

5.7 Autoboost Setting

The function is used to increase the cooling and heating capacity in 30 minutes once the operation starts.
This function is only available when the operation mode is Cool or Heat.
The unit starts each time in quick mode until the setting is canceled.
NOTES:
Autoboost cannot be set when the outdoor unit does not support this function.
Autoboost cannot be used if Power Savings is not supported.
When this function is activated while mode is "Cool", fan speed changes and is locked as "Auto" for 30
minutes at the longest regardless of the current setting. While in this operation (fan speed "Auto"), fan level
may drop as low as "Low" when the room temperature gets close to the setting temperature. The operation
starts regardless of the fan speed.
1. Set the autoboost
Step1. Select "Autoboost" on the "Function Menu" screen and
press "OK".
Step2. Press " " or " " , the selected items changes as follows:
"Not Set" ↔ "Cool" ↔ "Heat" ↔ "Cool + Heat".
Select the Autoboost mode and press "OK" to confirm the
settings.
Press " " to return to the "Function Menu" screen.
28
Function Menu
Power Consumption Display
Autoboost
Comfort Setting
Motion Sensor Setting
Setback Setting
OK
Select
Autoboost
Not Set
Cool
Heat
Cool + Heat
Select
OK
A16381TMEU