NEC EXP339 User Manual page 28

Table of Contents

Advertisement

Chapter 1 General Description
STATUS LED 1, 2 pattern
STATUS LED 1 STATUS LED 2
On (green)
Off
On (green)
On (amber)
Blinking (green) Off
Off
Off
Off
On (amber)
Off
Blinking (amber) Power Supply Unit is failing (in power
28
Description
The server is operating normally.
Initialization of BMC is in progress.
Memory is in a degraded state
In redundant power configuration, power is
not supplied to either of power unit.
The power is off.
Watchdog timer expired.
Memory dump is being requested.
Note: The LED remains green if the dump is
caused by software.
A temperature alarm was detected.
A CPU error occurred.
A PCI system error occurred
A PCI parity error occurred
A PCI bus error occurred.
A voltage alarm was detected.
A CPU temperature alarm was detected.
A correctable memory error has often
occurred.
An error occurred on Intel Node Manager
(one of the features of BMC Management
Console).
SEL area becomes full (1024 records)
redundant configuration).
A fan alarm was detected.
A temperature warning was detected.
A voltage warning was detected
One or more hard disk drives are
failing.(Only RAID system configuration with
2.5/3.5HDD hot-plug cage)
SEL area becomes 75% full (768 records)
Express5800/T110j User's Guide
4. Names and Functions of Parts
Action
Wait until initialization completes.
Find the device in degraded state by using
BIOS Setup Utility (SETUP), and replace it as
soon as possible.
Turn on the server.
Turn off the power and then turn it on.
If POST displays any error message, take
notes of the message, and contact your sales
representative.
Wait until the memory dump is completed.
Check the internal fan for dusts. Also check if
the fan unit is properly connected.
Turn off the power and then turn it on.
If POST displays any error message, take
notes of the message, and contact your sales
representative.
Contact your sales representative.
It is recommended to replace to new memory
as soon as possible.
Contact your sales representative.
Clear the SEL by Server Configuration Utility,
BMC Management Console or NEC ESMPRO
Manager.
Contact your sales representative.
Check if the internal fan cable is properly
connected.
Check the internal fan for dusts. Also check if
the fan unit is properly connected.
Contact your sales representative.
Clear the SEL by Server Configuration Utility,
BMC Management Console or NEC ESMPRO
Manager.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Express5800/t110jExpress5800 seriesExp339a

Table of Contents