9.3.4 Visual inspection
During the visual inspection, check all components for mechanical damage and leaks. Replace damaged
components immediately.
9.3.5 Leakage test
A leakage test is only possible if the QWIK‑PURE
1. Fill the QWIK‑PURE
2. Check all hose and other connections for leaks.
Error or fault pattern
Leaky hose connection
Bayonet catch leaking
End cap leaking
with tap water through the vent until water comes out of the condensate drain.
®
is completely filled with water.
®
Measure
•
Tighten the hose clamp.
•
Replace hardened hose and respective hose
clamps.
•
Check the fit of the seal and correct if necessary.
•
Check the seal for damage and replace if
necessary.
•
Tighten the bayonet fitting.
•
Check the seal for damage and replace if
necessary.
•
Check the fit of the seal and correct if necessary.
•
Check the seal for damage and replace if
necessary.
•
Tighten the end cap.
QWIK-PURE
®