Communications system analyzer
Table of Contents

Advertisement

DS
Description:
Command Syntax:
Parameters:
Notes:
DS
The
command sets the DTMF modulation source switch and specifies its
modulation level.
DS nl ,n2
Description:
optional:
Yes
Type:
<Decimal Numeric Program Darzu
units:
None
Resolution:
N/A
Range:
0: continuous
1: Off
2: Burst
Reset:
Description:
DTMF Modulation Level
optional:
Yes
units:
Mode dependent, see notes
Resolution:
Mode dependent, see notes
Range:
Mode dependent, see notes
Reset:
The following table describes the Units, Resolution, and Range values for the
Modulation Level based upon the RF-Control mode of the analyzer.
RF-Control
M o d e
Monitor/Narrow-Band
Monitor/Wide-Band
Generate/AM
Generate/FM/Narrow-Band
Generate/FM/Narrow-Band
Generate/PM/Wide-Band
Generate/PM/Wide-Band
U n i t s
R e s o l u t i o n
V
0.005 v
V
0.05 v
1 %
0.05 kHz
0.05 kHz
rad
0.01 rad
rad
0.1 rad
Motorola Communications Analyzer
Programming Reference
Range
0.000 - 0.795
0.00 - 7.95
0 - 99
0.00 - 9.95
0.00 - 9.95
0.50 - 2.00
10.0