Haier Ampac ZoneSense PLUS Operation Instructions Manual page 33

Table of Contents

Advertisement

Program
PROGRAM
MENU
ENTER
SELECT
MENU
ZONES
ZONE 1 - 8
ENTER
NORMAL
1 TO 8
SELECT
MENU
CLOCK
DAY
ENTER
TIME
THROUGH
DAY TIME
MCP ZONE
MCP ZONE
MENU
ENTER
Z #
Z #
SELECT
MENU
BELL
OUTPUTS
ENTER
ZN 1 TO 8
MENU
ENTER
1 TO 8
SELECT
MENU
RELAY
RELAYS
ENTER
1 TO 8
1 TO 8
SELECT
MENU
FIRE FAN
FAN
ENTER
1,2,3,4
1 TO 4
S E T
MENU
SOUNDERS
SNDR #
ENTER
12345678
MENU
INDICATE
SELECT
ENTER
STYLE
STYLE #X
DISPLAY
EDIT
MENU
########
ENTER
TEXT
SELECT
ZONE
MENU
Z LABELS
ENTER
EOL
EOL
MENU
ENTER
10uf
RES 3K3
AS FACTORY
DEFAULT
ZONE
ZONE
MENU
S/C
ENTER
ALARM
Agent Notes: If only one trigger zone is allocated a zone then the system will be activated by one zone only.
Any trigger zone may be allocated to any zone. However when a trigger zone has been allocated
eg T1 to zone 1 then only the remaining trigger zones T2, T3 or T4 are each available to be
allocated one of the remaining detector zones.
If multiple trigger zones are allocated eg T1 - Z1, T2 - Z2, T3 - Z3 then any one zone in alarm will
operate the first stage and any other zone in alarm will operate the second stage.
AVF
NON LATCH
LEGEND:
CHANGE
DAY TIME
MOV E
8
ASSIGN MCP
TO A ZONE
1
SELECT
SELECT
WARN
ACF
S Y S
ZN 1 TO 8
ZN 1 TO 8
O N
MENU
UPDATE MENU
ENTER
EXAMPLE OF ACTIVATING ZONE TO TURN ON/OFF SELECTED OUTPUT
OF F
R# Z-ALRM
R# Z-FLT
MENU
ENTER
1 TO 8
1 TO 8
O N
MENU
UPDATE MENU
ENTER
OF F
INHIBIT
ALARM
MENU
ZN 1 TO 8
ZN 1 TO 8
ENTER
O N
MENU
UPDATE MENU
ENTER
OF F
S E T
MENU
ZONE #
ENTER
12345678
MAX
SET STYLE FROM
1 TO MAX
AVAILABLE IN
MODULE
1
TO EDIT DISPLAY
EDIT
MENU
TEXT
TEXT USE
ENTER
EOL
EOL
RES4K7
RES 6K8
ZONE
FAULT
SREST 60
AGENT T1
ACF
MENU
ISOALTE PRESS ACF TO ISOLATE CIRCUITS EXTERNAL TO FACP
ENTER
ACF
CANCEL PRESS CANCEL AT ANY TIME TO BACK OUT OF THE MENU
CANCEL
ISOALTE
MENU
PRESS ENTER TO GO TO SUB MENU, SET MENU OR UPDATE PROGRAM
ENTER
PRESS MOVE FORWARD / BACKWARD THROUGH THE MENU
PRESS MOVE FORWARD THROUGH THE MENU
SELECT
SELECT
ASE
ALM OUT
ZN 1 TO 8
ZN 1 TO 8
R# Z-ISOL
R# I/P
1 TO 8
1 TO 8
BACKOUT OF MENU
CANCEL
LATCH
FUNCTION
3,4,5 WIRE
YES / NO
3
MENU
MENU
EXAMPLE OF SELECTING FUNCTION WIRE TO BE USED
4
ENTER
ENTER
5
THESE MENUS ARE ONLY AVAILABLE
IF RELAYS, FIRE FAN, SOUNDERS HAVE
BEEN CHANGED TO YES IN THE
FOR FULL INSTALLATION DETAILS REFER TO
MAN1565, ZONESENSE PLUS "ADD ON's"
TO MOVE THROUGH THE
ALPHABET / NUMBERS
EOL
RES 10K
MAN1564-3
AGENT T2
AGENT T3
SELECT
SELECT
BGD ALM 1
BGD ALM 2
ZN 1 TO 8
ZN 1 TO 8
R# SWITCH
RESET
1 TO 8
MENU
ENTER
Y E S
ACF ISOL
YES / NO
N O
NOTE:
SYSTEM MENU
TO MOVE THROUGH
THE WORD
AGENT T4
RESET
BUZZER
RESET
BUZZER
ACF ISOL
LATCH
33