NEC EXP803 Maintenance Manual page 201

Express server
Hide thumbs Also See for EXP803:
Table of Contents

Advertisement

Chapter 3 Appendix
l2nd
4
When installing an OS, starting system,
or applying Starter Pack
mlx4_bus
24
When starting system with
N8104-146/147 (InfiniBand board)
connected
ixgbt
27
When starting system, or applying
Starter
ixgbi
27
When installing an OS
volmgr
46
When installing an OS
Microsoft-Windows-
Time-Service
134
When installing an OS, booting the
system, or applying Starter Pack
disk
153
When creating logical drive by Universal
RAID Utility
Service Control
Manager
7023
When installing an OS
Service Control
Manager
7023
When installing an OS
Broadcom BCM57810 #xx: The network link is down. Check to make
Warning
sure the network cable is properly connected.
This event does not affect system operation.
MLX4_SF_32_0_0:
Problem - The port was configured to use auto sensing for deciding the
port type. The port * failed to detect the port type automatically.
Impact - As a result the port is started as IB port (unless the port is
ETH only). This may cause a connection problem if the other side is
Warning
ETH port.
Reason and suggestion to fix - This problem may happen since the
computer is connected back to back or the cable is unplugged.
For solving this issue connect the port to a switch or define the port type
explicitly (IB or ETH) instead of auto.
If Auto Negotiation fails in InfiniBand connection environment (e.g.,
InfiniBand cable is not connected), the port works as IB port. Thus, this
event does not affect system operation.
Intel(R) Ethernet Controller X540-AT2 #xx
Warning
Network link is disconnected.
This event does not affect system operation.
Intel(R) Ethernet Controller 10 Gigabit X540-AT2 #xx
Warning
Network link is disconnected.
This event does not affect system operation.
Error
Crash dump initialization failed!
Go to the following Microsoft website for details.
http://support.microsoft.com/kb/2756313
NtpClient was unable to set a manual peer to use as a time source
because of a DNS resolution error on 'time.windows.com,0x9'. NtpClient
Warning
will try again in 15 minutes and double the reattempt interval thereafter.
The error was: No such host is known. (0x80072AF9)
If it is not registered after connecting to the Internet, there is no problem
with system operation.
The IO operation at the logical block address for disk was retried.
Warning
* The on-screen message depends on your environment.
If this event is logged when creating a logical drive by Universal RAID
Utility, there is no problem in system operation.
The Network List Service terminated with the following error:
Error
The device is not ready.
If this event is logged only when installing an OS and does not occur
repeatedly, there is no problem in system operation.
The IP Helper service terminated with the following error:
Error
The service cannot be started, either because it is disabled or because
there are no enabled devices associated with it.
If this event is logged only when installing an OS and does not occur
repeatedly, there is no problem in system operation.