NEC Express5800/R120e-1M Instruction Manual page 130

Hide thumbs Also See for Express5800/R120e-1M:
Table of Contents

Advertisement

Chapter 3 Appendix
Error Message
B272
PCI Slot 1B - PCIe Link Speed
Error
B273
PCI Slot 2B - PCIe Link Speed
Error
B275
PCI Slot 1C - PCIe Link Speed
Error
B276
PCI Slot 2C - PCIe Link Speed
Error
B277
PCI Slot 3C - PCIe Link Speed
Error
B278
PCI Slot 1D - PCIe Link Speed
Error
DXE_PCI_BUS_OUT_OF_RESOURCES
B800
C000
The error occurred during
fan sensor reading.
C010
The error occurred during
temperature sensor reading
C011
System Temperature out of
the range.
C020
The error occurred during
voltage sensor reading.
C021
System Voltage out of the
range.
C040
SROM data read error
C061
1st SMBus device Error
detected.
C062
2nd SMBus device Error
detected.
C063
3rd SMBus device Error
detected.
C064
4th SMBus device Error
detected.
C065
5th SMBus device Error
detected.
C066
6th SMBus device Error
detected.
C067
7th SMBus device Error
detected.
C068
8th SMBus device Error
detected.
C101
BMC Memory Test
Failed.
C102
BMC Firmware Code
Area CRC check Failed.
C103
BMC core hardware failure.
BMC IBF or OBF check failed. An error was detected while
C104
C105
BMC SEL area full.
C10C
BMC update firmware
corrupted.
C10D
Internal Use Area of BMC FRU
corrupted.
C10E
BMC SDR Repository empty.
130
Cause
Link Speed error was detected
on PCI Slot 1B.
Link Speed error was detected
on PCI Slot 2B.
Link Speed error was detected
on PCI Slot 1C.
Link Speed error was detected
on PCI Slot 2C.
Link Speed error was detected
on PCI Slot 3C.
Link Speed error was detected
on PCI Slot 1D.
Resources to be allocated to
PCI expansion card was
insufficient.
An error was detected while
reading fan sensor.
An error was detected while
reading temperature sensor.
A temperature abnormality was
detected.
An error was detected while
reading voltage sensor.
A system voltage abnormality
was detected.
An error was detected while
reading data on SROM.
An error was detected on 1st
SM Bus.
An error was detected on 2nd
SM Bus.
An error was detected on 3rd
SM Bus.
An error was detected on 4th
SM Bus.
An error was detected on 5th
SM Bus.
An error was detected on 6th
SM Bus.
An error was detected on 7th
SM Bus.
An error was detected on 8th
SM Bus.
An error was detected on BMC.
accessing BMC.
There is not enough space to
store the system event log.
An illegality was detected while
updating BMC firmware.
An illegality was detected in
FRU containing the device
information.
An error was detected on BMC
SDR.
Express5800/R120e-1M, R120e-2M Maintenance Guide
Solution
Contact your sales representative.
It is possible that a fan has failed or is clogged.
Contact your sales representative.
Contact your sales representative.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same error
is detected repeatedly, contact your sales
representative.
Start up Offline Tools (Chapter 1, 9. Offline Tools)
and delete the event logs.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same error
is detected repeatedly, contact your sales
representative.
1. POST Error Message

Advertisement

Table of Contents
loading

Table of Contents