Chapter 1 Maintenance
[?]
The following message appears when installing OS, and cannot proceed:
→
The USB optical disk drive on which EXPRESSBUILDER is set may be connected to USB3.0 port.
Connect an optical disk drive to USB2.0 port. Refer to Chapter 1 (4. Names and Features of
Component) in User's Guide.
[?]
Unable to access the partition which was previously created after reinstalling while several disks are
connected
→
For details, refer to the Microsoft website below:
http://support.microsoft.com/kb/2497048/ja
[?]
When Windows Server 2012 is installed while several disks are connected, the system partition and the
boot partition (350 MB) are sometimes created in another disk
→
For details, refer to the Microsoft website below:
http://support.microsoft.com/kb/2530901/ja
[?]
When Windows Server 2008 R2 is installed while several disks are connected, the system partition and
the boot partition (100 MB) are sometimes created in another disk
→
For details, refer to the Microsoft website below:
http://support.microsoft.com/kb/2530901/ja
[?]
When Starter Pack is executed on Windows Server 2008 R2, the below message is sometimes displayed
for a moment upon shutdown
1 program still needs to close:
(Waiting for) Task Host Window
→
No problems for system operation.
For details, refer to the Microsoft website below:
http://support.microsoft.com/kb/975777/en-us
[?]
The system was installed as Workgroup although it is set to join the domain
Is the LAN cable properly connected?
→
If the LAN cable is not connected, the system is installed in workgroup setting, not in domain join setting.
After the OS is started, join the domain.
32
(Japanese only)
(Japanese only)
(Japanese only)
Express5800/R120e-1M, R120e-2M Maintenance Guide
5. Troubleshooting