Toshiba LF620F Instruction Manual page 119

Electromagnetic flowmeter converter
Hide thumbs Also See for LF620F:
Table of Contents

Advertisement

(2) Automatic selection of bidirectional flows multi-range with an internal signal
Reverse direction
Range output No.1
Range output No.2
Reverse to Forward direction change
Output
←Low cutoff
x 1.25
0
-(Low cutoff x 1.25)→
Reverse direction 0 Forward
Range output
ON
No.2
From reverse range to forward range
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
output (%)
125
Range 3
100
Range 4
Hysteresis
0
OFF
ON
ON
←Low cutoff x 1.25
4mA
Flow rate
Range output
OFF
- 118 -
Range 1
Range 2
Hysteresis
0
Forward direction
ON
Forward to Reverse direction change
Low cutoff x 1.25→
Low cutoff
x 1.25→
Reverse 0 Forward
ON
No.2
From forward range to reverse range
6 F 8 A 0 9 2 8
20mA
4mA
Flow rate
OFF
OFF
Output
0
← -(Low cutoff x 1.25)
Flow rate
OFF

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lf622f

Table of Contents