8.2.22 Preset Mode

The preset mode determines the function when the totalizer reaches the preset count.
The present mode can be set from the items shown below.
●Preset mode
  Selection items
Note: If you set the preset mode to "50ms PLS" or "500ms PLS", you need to set the preset
count to 1, 2, 5, 25, 125 ×10
preset output timing may be shifted when the totalizer overflows.
You can check or change the preset mode as described below.
The following is an example to change the present mode from Output condition hold (HOLD)
to One-shot pulse output with pulse width of 50ms (50ms PLS).
Switch operation
 
STEP1 
 
 
 
HOLD
50ms PLS
500ms PLS
Display example
K:PRESET C 
1 PRST VAL 
2 OUT MODE 
3 EXIT 
 
 
 
ESC
 
OUT MODE 
 
HOLD 
 
 
 
ESC 
 
− 90 −
Preset mode
Holds the output value.
Outputs a one shot pulse of 50ms width.
Outputs a one shot pulse of 500ms width.
n
. (If you set a value that does not meet this condition, the
Select "OUT MODE" from the setting item
selection menu.
The current setting (HOLD in this example)
appears.
Then push
* Pushing
ESC
screen.
6 F 8 A 0 9 2 7  
Description
.
returns you to the menu