Zanussi ZS12V70CCHI Service Manual page 16

Table of Contents

Advertisement

5.3.2 Connecting the cables
Capacity
System Voltage/
Watts / Btu/h
Frequency
3517/12000
220-240V/50Hz.
5280/18000
220-240V/50Hz
7034/24000
220-240V/50Hz
5.3.3 Electrical wires
12K Heat Pump Type Outdoor
L
N
S
blue
brown
yellow/green
3x1,5 mm² (Power Cable)
L
N
S
brown
blue
black
yellow/green
4x0,75 mm² (Signal Cable)
Indoor Unit Connection
12/18/24K
Heat Pump Type
1
2
3
4
brown
blue
yellow/green
4x0,75 mm²
Indoor Unit Connection
5.3.4 Piping length and the elevation
Capacity
Suction/Discharge
Pipe Diameter (mm)
Watts / Btu/h
Ø9,52(3/8")-6,35(1/4")
3517/12000
Ø12.7(1/2")-6,35(1/4")
5280/18000
Ø15,88(5/8")-6,35(1/4")
7034/24000
Outdoor unit
(A)
(B)
Indoor unit
Piping length under 5m
5.3.5 Important Installation Informations
• In order to avoid extraordinary noise and vibration, the authorized service personnel must apply a proper fixation of the air
conditioner.
• Do not block the air inlet or the air outlet.
• Do not use the unit in places with extremely high humidity.
• The wall must be strong enough to support the weight and vibration of the unit.
• Install the indoor unit at least 230 cm above the floor surface.
• The air filter should remain accessible.
• Install the indoor unit in a place where the condensate water can be easily drained.
Power Cord Cable
Connecting Cable
Gauge (mm²)
Gauge (mm²)
1,5
2,5
2,5
5
black
Standard
Maximum
Length (m)
Length (m)
4
15
4
15
4
15
Indoor unit
Piping length 5m or more
Fuse
Circuit
Type (A)
Breaker (A)
0,75
6,3
0,75
6,3
0,75
6,3
Maximum
Additional
Height (m) (A)
Refrigerant
(g/m)
5
15
5
25
5
30
Outdoor unit
(A)
Oil trap
(B)
16
16
16
20