Zanussi ZS12V70CCHI Service Manual page 57

Table of Contents

Advertisement

Steps
Procedure
Refrigerant components (4 way valve, capillary, etc.)
Remove the 3 screws fixing the isolation sheet and then remove the
isolation sheet.
Recover the refrigerant at first. Loosen fixing screw on condenser
connection. Disassemble the pipes in both inlet and outlet with
welding torch. Detach the condenser. After remove all condenser
connection screws, pull the condenser upwards to remove it.
Before handling the cooling system components ( compressor, con-
denser, 4way valve, capillary ) you have to recover the refrigerant first.
Unsolder the capillary, valves and the outlet pipe of condenser. Do
not block the capillary with welding slag during unsoldering
Remove the 2 screws fixing the gas valve. Unsolder the gas valve
and the air-return pipe.
NOTE: Discharge the refrigerant completely before unsoldering;
when unsoldering, wrap the gas valve with wet cloth to avoid dam-
age to the valve caused by high temperature.
NOTE: Discharge the refrigerant completely before unsoldering;
when unsoldering, wrap the gas valve with wet cloth to avoid dam-
age to the valve caused by high temperature.
Solder of the pipe connecting the compressor, condenser and valve
support. (Do not block the capillary during soldering.)
Compressor
To remove the compressor, you must first detach the brazed part of
the suction and the discharge pipe connected with compressor and
remove the 4-way and capillary.
Loosen the 3 nuts of compressor leg and remove the compressor.
XXXXX
Remove the 3 screws fixing the isolation sheet and then remove the
isolation sheet.