Zanussi ZS12V70CCHI Service Manual page 56

Table of Contents

Advertisement

Steps
Procedure
Reactor
Remove the reactor by loosen the 2 screws on the interconnection
plate.
Axial Fan
Loosen the screw fixing the blade. Remove the axial flow blade.
Motor Bracket and Fan Motor
Loosen the one tapping screw fixing the motor support. Raise the
support to remove it.
Loosen the 4 tapping screws fixing the motor. Disconnect the leading
wire of motor. Remove the motor.
Sponges
Remove the upper and enwrapped soundproof sponge by taking out
on the touch and close fastener.
56

Advertisement

Table of Contents
loading

Table of Contents