2.
Basic Functions
Backup (Advanced Copy)
When an REC is performed over a WAN, a bandwidth that supports the amount of updates
from the server must be secured. Regardless of the amount of updates from the server, a
bandwidth of at least 50Mbit/s is required for the Synchronous mode and a bandwidth of at
least 2Mbit/s for the Consistency mode (when data is not being compressed by network devi-
ces).
When an REC is performed over a WAN, the round-trip time for data transmissions must be
100ms or less. A setup in which the round-trip time is 10ms or less is recommended for the syn-
chronous transmission mode because the effect upon the I/O response is significant.
For REC, the data in the copy destination cannot be referenced or updated until the copy ses-
sion is suspended. If the monitoring software (ServerView Agents) performs I/O access to the
data in the copy destination, an I/O access error message is output to the server log message
and other destinations. To prevent error messages from being output, consider using other
monitoring methods.
When a firmware update is performed, copy sessions must be suspended.
The following models support REC Disk Buffers.
-
ETERNUS DX100 S4/DX200 S4
ETERNUS DX500 S4/DX600 S4
-
ETERNUS DX8900 S4
-
-
ETERNUS DX100 S3/DX200 S3
-
ETERNUS DX500 S3/DX600 S3
-
ETERNUS DX8100 S3/DX8700 S3/DX8900 S3
ETERNUS AF250 S2/AF650 S2
-
ETERNUS AF250/AF650
-
-
ETERNUS DX200F
-
ETERNUS DX90 S2
ETERNUS DX400/DX400 S2 series
-
ETERNUS DX8000/DX8000 S2 series
-
To use REC Disk Buffers, the controller firmware version of the ETERNUS DX must be
V10L60-6000 or later, or V10L61-6000 or later.
When the ETERNUS DX90, the ETERNUS DX400 series, or the ETERNUS DX8000 series is used
as the copy destination, REC cannot be performed between encrypted volumes and unencryp-
ted volumes.