The vise open/clamp switch must be turned to the right to "clamp" position before the blade
can start running.
6. *Saw bow up button
When this button is pressed, the saw bow rises until the operator release the button.
*If the optional angle display is installed:
DO NOT
rise the saw bow
beside angle scale will get pressed by saw bow and caused damage.
*Please refer to the optional accessory in page. 4-11 for more details.
While pressing the saw bow up button, it will also stop the running blade; please use the
emergency stop button in an emergency.
7. Saw bow down button
When this button is pressed, the saw bow descends until the operator lets go of the button or until
the saw bow touches the lower limit switch.
8. Vise clamp/unclamp selector switch
This selector switch works with the No. 9 Vise operation button. This selector switch is used to select
if the vise will clamp
For the blade to start running, the vise must be clamped.
9. Vise operation button
Press this button and the vise will clamp or umclamp according to No. 8 Vise clamp/unclamp selector
switch.
10. Blade speed indicator
Blade speed is shown here in predetermined unit (M/min or fpm).
All parameter settings have been done by our factory before shipment. Please do not make any
random change to the parameter as it may affect the accuracy of the blade speed reading. Please
consult your agent shall there be any need to reset machine parameters.
11. Blade speed control knob
Blade speed is controlled by the inverter located under the workbed. Turning the knob clockwise