Artisan 700/
Figure 4-166. Routing the Grounding Wire
(Artisan 700/PX700W/TX700W)
DISASSEMBLY/ASSEMBLY
Wire
Route the Grounding Wire between
the ribs
(x5) and frame.
Groove
Rib
Disassembly Procedures
https://www.manualsbooks.com

4.2.5.3 Scanner Carriage Unit

Parts/Components need to be removed in advance:
Scanner Unit/ADF Unit/ Scanner Upper Housing/Scanner Motor Unit
Removal procedure
Some of the parts of Artisan 800/PX800FW/TX800FW differ from
those of Artisan 700/PX700W/TX700W.
Unless otherwise specified, this section describes the procedures for
Artisan 800/PX800FW/TX800FW. The differences that may affect
the disassembly/reassembly procedures of Artisan 700/PX700W/
TX700W will be provided in " Reassembly" , etc.
Be careful no to damage the Rod Lens Array when removing
Scanner Carriage Unit.
Rod Lens Array
Figure 4-167. Handling the Scanner Carriage Unit