128 Technical data

UL/CSA markings

The ACS800-04, ACS800-U4 and ACS800-04M are C-UL US listed and CSA marked. The approval is valid
with rated voltages (up to 600 V).

UL checklist

The drive is to be used in a heated, indoor controlled environment. The drive
must be installed in clean air according to enclosure classification. Cooling air
must be clean, free from corrosive materials and electrically conductive dust. See
Ambient conditions
The maximum ambient air temperature is 40 °C (104 °F) at rated current. The
current is derated for 40 to 50 °C (104 to 122 °F).
The drive is suitable for use on a circuit capable of delivering not more than
100 kA rms symmetrical amperes at the drive nominal voltage (600 V maximum
for 690 V units) when protected by fuses given in the
table. The ampere rating is based on tests done according to UL 508C.
The cables located within the motor circuit must be rated for at least 75 °C
(167 °F) in UL-compliant installations.
The input cable must be protected with fuses. Circuit breakers must not be used
without fuses in the USA. Suitable IEC (class aR) fuses and UL (class T) fuses are
listed in this hardware manual.
For installation in the United States, branch circuit protection must be provided
in accordance with the National Electrical Code (NEC) and any applicable local
codes. To fulfill this requirement, use the UL classified fuses.
For installation in Canada, branch circuit protection must be provided in
accordance with the Canadian Electrical Code and any applicable provincial
codes. To fulfill this requirement, use the UL classified fuses.
The drive provides overload protection in accordance with the National Electrical
Code (NEC). See the firmware manual for setting. Default setting is off, must be
activated at start-up.
Brake chopper: ABB has brake choppers that, when applied with appropriately
sized brake resistors, allow the drive to dissipate regenerative energy (normally
associated with quickly decelerating a motor). Proper application of the brake
chopper is defined in

Disclaimer

The manufacturer shall have no obligation with respect to any product which (i) has
been improperly repaired or altered; (ii) has been subjected to misuse, negligence or
accident; (iii) has been used in a manner contrary to the manufacturer's instructions;
or (iv) has failed as a result of ordinary wear and tear.

Cybersecurity disclaimer

This product can be connected to and communicate information and data via a
network interface. The HTTP protocol, which is used between the commissioning
tool (Drive Composer) and the product, is an unsecured protocol. For independent
and continuous operation of a product, such connection via a network to the
commissioning tool is not necessary. However, it is the Customer's sole
(page 122) for specific limits.
Resistor braking
NEMA data
(page 131).
(page 114) fuse

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acs800-04mAcs800-u4

Table of Contents