Fujitsu AIRSTAGE UTY-DTGYZ1 Operating Manual page 37

Hide thumbs Also See for AIRSTAGE UTY-DTGYZ1:
Table of Contents

Advertisement

Notes
Address number input
RCG No.
Indoor Unit
Address
Note: Only half-size characters can be input.
Note
When the address sequence must
be changed, "Sort" button on "Sys-
tem Form" sheet can be used.
Notes
When "Sort" / "Export Data" button was clicked and there is an error in the entered address, it is auto-
matically checked and an error is generated. If there are no errors, the file is output.
Entered data error. RCG No. is a value other than blank or
1-400. Enter correct data.
Entered data error. Refrigerant Circuit Address is a value other
than blank or 0-99. Enter correct data.
Entered data error. Indoor Unit Address is a value other than
blank or 0-63. Enter correct data.
Entered data error. Remote Controller Address is a value other
than blank or 0-15. Enter correct data.
Entered data error. RCG No. is not sequential. Enter correct data.
Entered data error. Remote Controller Address of master unit is
not 0. Enter correct data.
Entered data error. Remote Controller Address of slave units is
not sequential. Enter correct data
Entered data error. Remote Controller Address of slave units is
incorrect. Enter correct data.
Entered data error. Address is duplicated. Enter correct data.
En-36
1
2
Refrigerant
Circuit Address
Remote Control-
ler Address
Error message
Notice
When editing at the file making sheet and importing the
data to the touch panel controller, pay attention to the
following points.
Since the registered indoor unit data is overwritten and
the following data are changed when data is imported,
always confirm the data after setting.
Group setting data
Schedule data (unit setting)
History (outdoor unit and indoor unit errors and opera-
tion)
Edit the contents of "RCG No.", "Refrigerant Circuit Ad-
a
dress", "Indoor Unit Address", and "Remote Controller
Address".
Notes
Contents which can be set
RCG No.
Select and enter the remote controller group
(Remote Controller
by consecutive No. from 1.
Group No.)
However, make the same remote controller
group the same number.
(However, RCG No.:1 cannot be changed.)
Refrigerant Circuit
Enter the refrigerant system address (0-99).
Address
Unit Address
Enter the indoor unit address (0-63).
Remote Controller
Enter the remote controller address (0-15).
Address
Input sequentially beginning from 0.
At the end of all editing, save the file.
Click "Export Data" button.
b
∙RCG No. is blank or a value other than 1-400.
∙Refrigerant Circuit Address is blank or a value other than
0-99.
∙Indoor Unit Address is blank or a value other than 0-63.
∙Remote Controller Address is blank or a value other than
0-15.
∙RCG No. is not consecutive.
∙Master Remote Controller Address is not 0.
∙Slave Remote Controller Address is not consecutive.
∙Slave Refrigerant Circuit Address is incorrect.
∙Address is duplicated.