Appendix 2
When using DB Connection Service on the database server, the ODBC setting for the database used is required to be set in
advance.
The following shows the procedures for the ODBC setting.
For details on the setting method, refer to the manuals and online help of the operating system and the security software
used.
Starting ODBC Data Source Administrator
Enter the following command in the command prompt in accordance with the software version of MX MESInterface-R and the
bit version of DB Connection Service to be used.
Software version
'1.03D' or earlier
'1.04E' or later
APPX
116

Appendix 2 ODBC Setting

ODBC Setting
Bit version of DB Connection
Service
32-bit
64-bit
Command
"%SystemRoot%\SysWOW64\odbcad32.exe"
"%SystemRoot%\system32\odbcad32.exe"