Motorola iDEN i930 Field Service Manual page 109

Basic and field level test procedures
Hide thumbs Also See for iDEN i930:
Table of Contents

Advertisement

MECHANICAL PARTS REWORK AND REPAIR: REWORK PROCEDURE FOR COMPONENTS UNDER SAME SHIELD OF AN
It is mandatory to wear eye protection (Goggles) during cutting procedure.
WARNING:
NOTE: Boards with 72 hours or more of exposition need to be baked for 24 hours @ 125°C
prior to rework.
1. Carefully cut shield (See drawing) using a sharp and pointy cutter to detach shield from epoxy.
Do not use cutter vertical to the board to avoid damaging components with
NOTE:
cutter's tip
2. Pull cut shield and dispose it to a safe container
NOTE: Inspect for:
Additional epoxy (Extend cutting if necessary),
Lifted edges (Press them down if necessary),
Damaged components, or
Metal residues (Blow area if necessary).
3. With probe or pick remove epoxy from top of components if any.
4. Place board on fixture
5. Cover with heat-protector # 190532 (It must lay flush to the cut shield)
9.8.2
Shield Removal Procedure
Preparation: Place adequate Nozzle in the hand-piece of the Hot Air Machine. Set desired air
o not use pre-heater acceleration if "X-kar X-1001s" equipment is being
NOTE: D
used.
6. Protect any heat-sensitive component by placing appropriate Heat Shield over (If necessary)
9-12
.
pressure. Set Temperature: Top 330°C – Bottom 100°C
68P80401P03-O

Advertisement

Table of Contents
loading