In the SNMP category, you can enter system information and community
strings. You may also designate which stations can manage the Remote
Console Switch as well as receive SNMP traps from the switch. For more
information on traps, see "Enabling Individual SNMP Traps" on page 150 in
this chapter. If you check Enable SNMP, the unit will respond to SNMP
requests over UDP port 161.
NOTE:
The on-board web interface does not use standard SNMP to control
switches and therefore does not use UDP port 161. The on-board web interface
uses a secure, proprietary protocol to communicate with the Remote Console
Switches over a different network port.
Figure 7-5. SNMP Configuration Window
To configure general SNMP settings:
1 Click the Configure tab in the on-board web interface, then click the
SNMP category in the left column.
2 Click to enable the Enable SNMP check box to allow the Remote Console
Switch to respond to SNMP requests over UDP port 161.
3 Type the system's fully qualified domain name in the Name field, as well as
a node contact person in the System section.
149
Managing Your Remote Console Switch Using the On-board Web Interface