CHAPTER 9 Chapter System Startup/Shutdown and Power Control

9.4 Automatic Partition Restart Conditions

Menu Item
Reset
NMI
sadump
For details on setting for Windows shutdown, see
9.4
Automatic Partition Restart Conditions
This section describes the setting of conditions to execute automatic partition restart.

9.4.1 Setting automatic partition restart conditions

Users with Administrators/Operator privilege can set all the partitions, however, only users with Partition
Operator privilege can set the permitted partitions.
Note
-
If you perform following operations, disable 'Boot Watchdog'..
-
Installation of operating system
-
Starting in the single user mode
-
Backup/ restoration by System cast Wizard Professional
When the above mentioned operations are executed with the Boot Watchdog in the [Enable] status,
the specified action (Stop rebooting and Power Off or Stop rebooting or Diagnostic Interrupt assert)
will be executed after repeating the operating system restart for specified number of times. The
number of retries to restart the operating System and the actions to be executed depend on the
settings in the [ASR (Automatic Server Restart) Control] window of the MMB.
At that time, Boot Watchdog can be forcibly set to [Disable] by checking the check box of [Cancel Boot
Watchdog] and clicking the Apply button in the [ASR (Automatic Server Restart) Control] window.
The procedure of automatic restart condition setting of the partition is as follows.
1. Click [Partition] - [Partition#x] - [ASR Control].
-> The [ASR Control] window appears.
Scheduled
operations
Not supported
Resets any partition. This reset is not followed by a
reboot of the operating system.
Not supported
Issues an NMI interrupt for any partition.
Not supported
Instructs sadump for a partition.
'Appendix I Windows Shutdown
203
Description
Settings'.