CHAPTER 11 Error Notification and Maintenance (Contents, Methods, and Procedures)
11.4 Collecting Maintenance Data
Be sure to check with a field engineer before clearing events stored in the SEL.
Remarks
-
If a problem occurs during operation, e-mail notification is sent. For details on how to specify whether
to use e-mail notification and how to set the error level and e-mail destination for e-mail notification,
see 1.5.11 [Alarm E-Mail] window in the PRIMEQUEST 2000 Series Tool Reference (C122-E177EN).
-
For an explanation of display items in the [System Event Log] window, see 1.2.2 [System Event Log]
window in the PRIMEQUEST 2000 Series Tool Reference (C122-E177EN).
-
To get the log of RAID card by downloading SEL, it is required that the partition mounting the
particular RAID card is power on state.
Downloading the event data stored in the SEL
A Fujitsu certified service engineer needs the event data stored in the SEL to analyze the system status.
Therefore, we may ask you to download the event data and submit it to a Fujitsu certified service engineer.
Procedure
1. Click the [Download] button in the [System Event Log] window.
A dialog box for specifying the storage file and path appears.
2. Enter the pathname.
The event data stored in the SEL is downloaded to the PC displaying the [Web-UI] window.
Filtering the events to display
Procedure
1. Click the [Filter] button in the [System Event Log] window.
The [System Event Log Filtering Condition] window appears.

FIGURE 11.13 [System Event Log Filtering Condition] window in PRIMEQUEST 2400E and 2800E