CHAPTER 3 Component Configuration and Replacement (Add, Remove)
3.3 Replacing components

3.3.1 Replaceable components

Replaceable components and replacement conditions are listed in the table below.
TABLE 3.10
Component name
PSU_P/PSU_S
FANM
FANU
FANM
SB
CPU
DIMM
Mezzanine
DIMM
PCI Express card
FBU
HDD/SSD
Battery
IOU_1GbE/IOU _10GbE
PCI Express card
DU
PCI Express card
FBU
HDD/SSD
MMB
OPL
MP, PDB
PCI_Box
IO_PSU
IO_FAN
PEXU
PCI Express card
*1: Possible only in configuration.
*2: Possible only for redundancy configuration with RAID.
*3: Possible only for MMB duplication configuration.
*4: PCI hot plug function is required. Operation by maintenance staff is optional.
*5: DR function is required.

3.3.2 Component replacement conditions

This section describes the replacement conditions of each component.
PSU
The PSU unit can be replaced while the system continues operating. PSU replacement in a non-redundant
configuration requires the system to be stopped.
FAN
The FAN unit can be replaced while the system continues operating.
SB
If the DR function (SB hot remove and SB hot add) is used, the SB can be replaced even when the partition
using the SB is powered on. When the DR function is not used, the SB can be replaced if the partition using
the SB is powered off.
Remarks
Since the CPU/Mezzanine/DIMM/PCI Express card /FBU which is mounted on the SB can be replaced after
removing the SB from the device, the replacement can be done under the same conditions as the SB.
Note
Replaceable components and replacement conditions
AC power off
(Device stop)
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable (*3)
Replaceable
Not replaceable
Replaceable
Not replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
49
AC power on
AC power on
status All
target partition
partitions off
off (hot
status (hot
maintenance)
maintenance)
Replaceable (*1)
Replaceable (*1)
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable
Replaceable (*3)
Not replaceable
Not replaceable
Replaceable
Replaceable (*1)
Replaceable (*1)
Replaceable
Replaceable
AC power on
target partition
on ( hot
maintenance)
Replaceable (*1)
Replaceable (*1)
Replaceable
Replaceable
Replaceable (*5)
Not replaceable
Not replaceable
Not replaceable
Not replaceable
Not replaceable
Not replaceable
Replaceable (*2)
Not replaceable
Replaceable (*5)
Not replaceable
Not replaceable
Not replaceable
Not replaceable
Replaceable (*2)
Replaceable (*3)
Not replaceable
Not replaceable
Not replaceable
Replaceable (*1)
Replaceable (*1)
Not replaceable
Replaceable (*4)
C122-E175-02EN