SECTION 400
(Version
3.0)
DBS
Issue 1 January
1990
FF-1 System
mode
FFl-3#-9#-
(I-
12)#
Extension park hold
recall timer
If an extension
place a call in their
park orbits,
and
leaves the call there
for longer
than the specified
time, the call will recall to the extension.
O#:No
recall
1 #:Recall
after
20 seconds
2#:Recall
after 40 seconds
3B:Recall
after
60 seconds
4#:Recall
after 80 seconds
S#:Recall
after
100 seconds
68:Recall
after
120 seconds
7#: Recall after
140 seconds
8#: Recall after
160 seconds
9#:RecalI
after
180 seconds
1 O#:Recall
after 200 seconds
11 #:Recall
after 220 seconds
lZ#:Recall
after 240 seconds
FFl-3#-lO#-(l -
12)#
Call reversion timer for attendant
If an outside
line call which
has been put on hold
by the attendant's
phone
is not answered
by an
extension
other than the attendant's
phone
within
the specified
time,
it is
transferred to the
attendant's
phone
and the extension's
recall timer
does not function.This
function
is not possible
when
the
system
is in the night
mode.
O#:No
Reversion
call
1%: Reversion
call after 20 seconds
2#:Reversion
call after 40 seconds
3#:Reversion
call after
60 seconds
4#:Reversion
call after 80 seconds
S#:Reversion
call after
100 seconds
6#:Reversion
call after
120 seconds
7f:Reversion
call after
140 seconds
S#:Reversion
call after
160 seconds
9#:Reversion
call after 180 seconds
101:Reversion call after 200 seconds
11 #:Reversion call after 220 seconds
12f:Reversion
call after 240 seconds
FFl-3#-1
l#- (I- 15)#
Unsupervised conference
monitor time
(CO -CO conference
monitoring
timer)
The time for which
a call is enabled
through
an
outside
line when
made from
DISA or when
conducted
through
or&de
lines only can be
restricted
within
the range
of 0 to 75 minutes.
If the specified
time is exceeded,
the outside
lines
are automatically
cut off.
O#:Disable
l#:UptoSmin.
2R:Un to 10 min.
3#:Up
to 15 min.
4#:Up
to 20 min.
5X:Up
to 25 min.
6#:Up
to 30 min.
7#:Up
to 35 min.
S#:Upto40min.
9#: Up to 45 min.
lO#:Upto
50 min.
ll#:UptoSSmin.
12#:Up
to 60 min.
13#:Up
to 65 min.
14#:Upto
70 min.
1 S#:Up
to 75 min.
Note:
It is necessary to set for
outside
calls
made
from DISA and calls through outside lines
only separa teiy.