SECTION 400 (Version
3.0)
Issue 1 January
1990
DBS
FF-2 Trunk
mode
FF2-(l-
32)#-16#-(0
or l)#
Call Diversion
(Trunk
to trunk
connection
trunk
setting)
tt is set whether
or not an outside
line can make a
trunk to trunk
connection.
This function
can be used at an extension
where
trunk to trunk
connection
has been set in the
extension
mode.
In addition,
if the time set with
the call
monitoring
timer
is exceeded,
the call is
automatically
cut off.
O#: Trunk to trunk
connection
not possible
l#: Trunk to trunk
connection
possible
FFZ-(1 - 32)#-17#-(0
- 9)#
Incoming ring signal pattern setting
The ring tone
pattern
for incoming
calls can be
changed
for each trunk
port
If outside
lines are assigned
for use to each
individual,
they will know
who the call is for by
the ring tone pattern
and this will facilitate
answering.
O#: lncominq
rinq tone svnchronized
1#:3secON/l
secOFF
2%:2secON/Zsec
OFF
38: 1 set ON I1 set OFF
4#: 1 set ON / 2 set OFF
59: 1 set ON / 3 set OFF
6#: 0.5 set ON / 0.5 set OFF
b 7#: 0.5 set ON IO.5 set OFF
and O.Ssec ON 12.5 set OFF
8#:0.5secON/3.5sec
OFF
9t:
1 set ON / 7 set OFF
FF2-(1-32)#-18#-
(I- 15)#
-
Outside line
disconnectsignal
detection
timer
If the signal indicating
that an outside
line has
been disconnected
during
a outside
call or while
it
is on hold is received,
or if the outside
line has
been cut off, the system automatically
cancels the
outside
line call. However,
as the call ends
automatically
when the outside
line is instantly
cut
due to the conditions
for the connected
PBX, it is
accommodated
by this setting.
The time
from when
it is determined
that the call
has been
disconnected
orthat
it has been disabled
to when the outside
line call status is
automatically
canceled
can be set within
the
range of 50 - 750ms.
(%&No
detection
(Keep the connection)
19:Dixonnection
bythe
morethan
50msrignal
2#:Dixonnection
by the more than
lOOms signal
3#:Disconnection
by the more than 150ms signal
4b:Dixonnection
by the more than 2OOms signal
S#:Disconnection
bythe
more than 250ms signal
6#: Disconnection
by the more than 300ms signal
7#:Disconnection
bv the more than 350ms siqnal
8#:Dixonnection
by the more than 400ms signal
9#:Dixonnection
by the more than 450ms signal
1 O#:Dixonnection
by the more than 500mr
signal
1 1 #: Disconnection
by the more than 550ms signal
128:Disconnection
by the more than 600ms signal
13#:Dixonnection
bythe
more than 650ms signal
14Y:Dixonnection
by the more than 700ms signal
158:Disconnection
bythe
more than 750ms signal