Panasonic 308 Installation Instructions Manual page 83

Small digital business system
Hide thumbs Also See for 308:
Table of Contents

Advertisement

/- .
-
Section 400
Issue 1 July 1990
(01-06)
OS#-(0,
1 or 2)#
S-DBS Programming
Instructions
VI.0
.~_._.~.
DTMF
SIGNAL
SENDING
TIME
TABLE
(AFTER
DIALING)
O#: 160 ms
l#: 320 ms
2#:480
ms
NOTE:
See also address (01-06) 07# on page 38.
(01-06)
09#-(0,
1 or 2)#
d
OUTSIDE
LINE DISCONNECT
CPC SIGNAL
DETECTION
The system automatically
cancels a CO line call if a disconnect signal is received.
,.---'i
'C_
O#: No detection of CPC sisal
l#: Detection only while on HOLD
2#: Detection anytime
(0146)
10#-fO,l-7)#
OUTSIDE
LINE DISCONNECT
CPC DETECTING
TIMER
The disconnect timer can be set within a range of 48 ms to 704 ms.
O#: More than 48 ms
l#: More than 96 ms
2#:
More than 192 ms
3#: More than 304 ms
4#:
More than 400 ms
5#:
More than 496 ms
6#:
More than 592 ms
7#:
More than 704 ms
-----.-
~-- - -----
.-