Technical Data - ABB Tina 7A Original Instructions Manual

Adaptor unit
Table of Contents

Advertisement

6

Technical data

Manufacturer
Address
Article number/Ordering data
Power supply
Operating voltage
Total current consumption
Current through safety device contacts
Short circuit current between contacts
Time delay t (in/out)
Voltage supply at normal operation (protection OK)
and 24 VDC supply voltage
General
Protection class
Ambient temperature
Humidity range
Housing material
Connectors
Mounting
Size
Weight
Colour
Safety / Harmonized Standards
Conformity
IEC/EN 61508-1...7
EN 62061
EN ISO 13849-1
EN 954-1
Certificates
2TLC172139M0201, rev. B
2013-03-02
ABB AB / JOKAB SAFETY
Varlabergsvägen 11
SE-434 39 Kungsbacka
Sweden
Tina 7A: 2TLA020054R0700
24 VDC +15 %, -25 %
47 mA (57 mA with max information output)
Information output: Max 10 mA
12 mA
10 mA
t < 70 µs
Dynamic input: between 9 and 13 volt (RMS)
Dynamic output: between 9 and 13 volt (RMS)
Information output: ~ 23 VDC
IP20
Storage: -30...+70°C
Operation: -10...+55°C
35 to 85 % (with no icing or condensation)
PVC
5-pin connection block (power supply, dynamic in/out, info)
4-pin connection block (safety loop A1-A2, B1-B2)
DIN-rail
62 x 46 x 13 (L x W x H)
~ 35 g
Black
European Machinery Directive 2006/42/EC
EN ISO 12100-1:2003, EN ISO 12100-2:2003,
EN 60204-1:2007, EN 954-1:1996, EN ISO 13849-1:2008,
EN 62061:2005
-9
SIL3, PFH
: 4.50*10
d
SIL3
Performance level: Pl e, category 4
Category 4
TÜV Nord
10
www.abb.com/ jokabsafety

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

2tla020054r0700

Table of Contents