Main-MJ (EXT)
harness (black)*
Main-MJ (LINE)
harness (yellow)*
Hole provided in the
lower MJ/PS shield
For 200 V series
Main-MJ (EXT) harness (black) *
Main-MJ (LINE) harness (yellow) *
Cable guide on the
MJ PCB insulator *
Power supply harness
Note for models with a power inlet having a built-in fuse
If the fuse built in the power inlet has blown, the power supply PCB could also be
damaged. Be sure to replace the whole power supply PCB ASSY, not just the fuse. Never
use any substitute or short-circuit the fuse terminals with conductors. Using a power inlet
with an unauthorized fuse will cause a fire or accident.
Power supply shield
Shield supports on the
power supply shield
MJ PCB *
PS insulator 200V
Power supply PCB
6-57
Lock of the lower
MJ/PS shield
Power supply harness
Hole provided in the
lower MJ/PS shield
Top view
Ferrite core
Cable guides on the
AC cord holder
Power cord
Route the power cord
under this tab.
(6_50_3_200V)
(6_51_1_200V)
*For MFC only