DCPJ140W
(1) Enter 5 and 4 in this order using the
maintenance mode.
The "SCAN ADJ SELECT" appears on the LCD.
(2) To adjust the right and left edges of horizontal scanning, enter 0 to display "RL EDGE *"
on the LCD.
To adjust the top edge of vertical scanning, enter 1 to display "TOP EDGE *."
To adjust the bottom edge of vertical scanning, enter 2 to display "BOTM EDGE *."
In the messages above, an asterisk (*) denotes the current correction value.
(3) Measure the right, left, top and bottom margins on the printout of scanned data.
(4) Enter the measured values (in units of 0.1 mm) multiplied by 10.
To increase the current correction value by 10 (1.0 mm), press the
press the
key. Then press the OK key.
To increase the current correction value by 1 (0.1 mm), press the
press the
key. Then press the OK key.
NOTE: Pressing the Stop/Exit key instead of the OK key cancels the newly entered values
and returns to the initial stage of the maintenance mode.
(5) Press the OK key.
The machine displays "ACCEPTED" on the LCD and returns to the initial stage of the
maintenance mode.
,