CHAPTER 3 Work before Operating System Installation
3.5 Partition Configuration (Extended Partitioning)
[IPv6 Console Redirection Setup] window
1.
Click [Partition] - [Console Redirection Setup] - [IPv6 Console Redirection Setup] window.
[IPv6 Console Redirection Setup] window is displayed. For details on window, see "1.3.3 [Console Redirection
Setup] window" of PRIMEQUEST 2000 series Tool Reference (CA92344-0539).
FIGURE 3.37
2.
Set IP address and the prefix length to access Console Redirection LAN for IPv6. When it is set automatically, IP
address and the prefix length is acquired by clicking on [Auto] button.
3.
Enable video redirection and virtual media respectively.
4.
Click [Apply] button.
3.5.8 Power OFF and ON of the Extended Partition
Power OFF and power ON are required for each Extended Partition to reflect the configuration change in the Extended
Partition. For the details of Power OFF and power ON, see
3.5.9 Confirmation of Extended Partition information
The status of the partition and the partition related information is displayed.
The partition configuration of the entire system of PRIMEQUEST 2000 series can be confirmed even by the [Partition
Configuration] window.
Operations
1.
Click [Partition]-[Partition#x]-[Information].
[Information] window is displayed. For details on [Information] window, see " [Information] window" of "1.3.8
[Partition#x] menu" of PRIMEQUEST 2000 series Tool Reference (CA92344-0539).
Example of [IPv6 Console Redirection Setup] Window
"CHAPTER 7Power ON and OFF of the
57
partition".
CA92344-0536-01