After Installation, Connecting San With Internal Hdd/Ssd; Procedure To Install Vmware 5.X On The San Storage Device; Presetting - Fujitsu PRIMEQUEST 2000 Series Installation Manual

Primequest 2000 series
Hide thumbs Also See for PRIMEQUEST 2000 Series:
Table of Contents

Advertisement

CHAPTER 4 Installation of Operating System and bundled software

4.7 Procedure to install VMware 5.x on the SAN storage device

Any changes is not needed for core_collector
[Note] RHEL6.5 improves memory usage of the makedumpfile command.
c. Reboot
5.
NTP client is configured.
NTP server on the operating system side is configured.
For details, see
6.
Save the management information and configuration.
For details, see
7.
UPS battery monitor is set.
When the duration of life of the UPS battery is monitored: see "Setting for component replacement alert for
PRIMEQUEST ". This document is downloaded from the following URL.
http://www.fujitsu.com/global/products/computing/servers/mission-
critical/primequest/documents/manuals/
8.
Watchdog Timer allows reboot OS in case that OS freezes.
passes.
For details, see "8.4 Automatic Partition Restart Conditions" of PRIMEQUEST 2000 series Administration
Manual (CA92344-0537).

4.6.5 After installation, connecting SAN with internal HDD/SSD

See PRIMEQUEST 2000 Series SAN Boot Environment Configuration Manual (C122-E206EN), for connecting SAN with
internal HDD/SSD, after installation.
Moreover, for details on driver parameter, see readme of the driver supplied.
4.7
Procedure to install VMware 5.x on the SAN storage device
This section briefly describes the procedure by which VMware 5.x is installed on the SAN storage device. Start the
installation after confirming the MMB configuration and successful to log in to the MMB. For the details of SAN storage and
FC card,
Converged Network Adapter and NIC for iSCSI Boot
Environment Configuration Manual (C122-E206EN).

4.7.1 Presetting

Set the following if necessary.
1.
Set the LUN of the SAN storage device.
2.
[PCI ROM Priority] of BIOS is set.
- For the UEFI Install
- Set [Device Manager]-[PCI Subsystem Configuration]-[PCI ROM Priority] of BIOS menu to "EFI Compatible
ROM".
- For the UEFI Install:
- Set [Device Manager]-[PCI Subsystem Configuration]-[PCI ROM Priority] of BIOS menu to "Legacy ROM".
- Set [Device Manager]-[PCI Subsystem Configuration]-[OpROM Scan Configuration] of BIOS menu to "Enable"
only for booting Device.
3.
Set the BIOS to recognize LUN of the FC card,
For setting the FC card, see "Chapter 2 Setting of fiber channel card (FC card)" of PRIMEQUEST 2000 Series SAN
Boot Environment Configuration Manual (C122-E206EN).
4.
Check the setting of the partition by MMB after removing the internal HDD/SSD of PRIMEQUEST.
-
SB/IOU configuration is set
See
-
Console redirection is set
See
-
Video redirection: Enable
-
Virtual media: Enable
-
Various modes are set
"5.6 Setup of NTP
client".
""5.7 Saving management and configuration
"3.4.1 Setting the partition
configuration"
"3.4.6 Settings of Console
Redirection"
information".
Rebooting OS is executed when the set time
settings, see PRIMEQUEST 2000 Series SAN Boot
Converged Network Adapter and NIC for iSCSI
76
Boot.
CA92344-0536-01

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Primequest 2800e

Table of Contents