SPE Hardware, Installation, and Maintenance Manual

Programming the KSU for SPE(M)-U( )

S P E ( M ) - U ( ) E T U

Programming Requirements

The SPE(M)-U( ) ETU is programmed as a MIF(M)-U( ) ETU. There is not an
SPE card-type in system programming.
Use the following memory blocks to program the system for the SPE(M)-U( )
ETU.
Not all memory blocks will apply; use the ones necessary to configure
the application.
MB 7-1 Card Interface Slot Assignment to assign the appropriate slot for
a MIF(M)-U( ) ETU.
MB 7-3-01 MIF (LCR) Assignment to assign the LCR functions to the
MIF(M)-U( ) ETU if using the LCR function.
MB 7-3-04 MIF (Caller ID) Assignment to assign the class functions to
the MIF(M)-U( ) ETU is using the Caller ID Scrolling feature.
MB 1-8-35 COM Port Baud Rate Setting Assignment to assign the
appropriate baud rate for COM 1 and COM 2 for PC Programming and
SMDR if needed.
MB 1-8-36 COM Port Parity/Stop Bit Setting Assignment to assign the
appropriate parity and stop bit for COM 1 and COM 2.
MB 1-8-38 Modem Number for Remote Programming Assignment,
assign the modem extension number for the built in modem when using
the internal modem of the SPE(M)-U( ) ETU.
MB 1-8-18 Site Name Assignment, assign a site name for PC
programming access if needed.
MB 1-8-17 PC Programming Password Assignment, assign a password
for PC programming access if needed.
2 - 1