Network Folder
Use the Network folder to configure network timing parameters used to monitor the link
between a Gateway and router, hub, or switching device to which the unit is connected. When
link failure is detected, the error condition is reported.
Also use the folder to enter the Gatekeeper's ID, the location of a second Gatekeeper if present,
and to configure Gatekeeper bandwidth management.
Use the Information Section to view and edit network timing parameters.
Regular time
period
Error detect time
period
Disconnect after
errors
Installation Manual
Type the timing cycle over which the error checking packets will be
transmitted during normal operation.
The seconds value can also be scrolled up and down with the scrolling
arrows located to the right of the field.
Type the timing cycle over which the error checking packets will be
transmitted after an error has been detected. This value is usually set to a
higher frequency than Regular Timing. If a normal return is detected
during this period, the Regular Timing is resumed.
The seconds value can also be scrolled up and down with the scrolling
arrows located to the right of the field.
Type the number of times that an error can be detected before the link is
failed.
The times value can also be scrolled up and down with the scrolling
arrows located to the right of the field.