Em Server Power Supplies; Ipmi Fru Address; Power Supply Failure; Rear Panel Connections - Toshiba IP edge EP Installation Manual

Hide thumbs Also See for IP edge EP:
Table of Contents

Advertisement

EM SERVER POWER SUPPLIES

Rear Panel Connections

Rear Panel Button
Redundant Power
Supplies
PS #1
PS #2
PS1 LED
PS2 LED
Figure 2-5 IPedge EM Server - Rear panel Connectors
EM SERVER POWER
SUPPLIES

IPMI FRU Address

Power Supply Failure

2-6
The rear panel connectors and indicators are described below.
AC power - Each of the two power supply modules has an AC power cord
connector. Refer to
Figure
Keyboard and PS/2 Mouse
USB 0 and USB 1
COM1
VGA
LAN1 and LAN2
IPMI LAN
There is a UID LED and button on the rear panel to the right of the LAN 2
connector.
PS/2
IPMI Connector
Mouse
Keyboard
USB
COM 1 VGA
The IPedge EM Server has dual redundant power supplies. In the event
of a power supply failure the failed supply will go off-line, the surviving
supply will supply all of the power and allow the system to continue
operation without interruption.
The power supply module IPMI FRU addresses are 72 and 70. The
modules, as viewed from the rear of the chassis 70 (binary 1110 000) on
the right, 72 (binary 1110 001) on the left or outside.
If either of the power supply modules fail, the Universal Information (UID)
LED on the control panel will blink slowly to indicate a failed power supply
module. The UID LED will continue to blink until the failed module has
been replaced. Also, the power supply LED, on the rear panel will change
from green to amber on the failed unit. The failed unit will issue a
continuous beep tone. The power supply modules have a hot-swap
capability, you can replace the failed module without powering down the
system.
2-5.
UID
Button
LAN 1 LAN 2
UID
LED
Installation Manual
Rear Panel Connections
August, 2011

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ip edge emIp edge ec

Table of Contents