Table 1.56 Display Items And Set Items Of [Power Control] Window - Fujitsu PRIMEQUEST 2000 Series Tool Reference

Hide thumbs Also See for PRIMEQUEST 2000 Series:
Table of Contents

Advertisement

MMB Web-UI (Web User Interface) Operations
1.3 [Partition] Menu for PRIMEQUEST 2400E2/2800E2/2400E/2800E

TABLE 1.56 Display Items and Set Items of [Power Control] Window

Items
#
P#
Partition Name
Power Status
System Progress
Displays the number by which the partition is identified.
[In case of the PRIMEQUEST 2800E2/2800E model]
There are 0-11 Partitions.
[In case of the PRIMEQUEST 2400E2/2400E model]
There are 0-5 Partitions.
However, only the partitions with SB and IOU registration are displayed.
Displays the "P" which indicates the parent Physical Partition from the physical
partition wherein Extended Partitioning Mode is set to Enable. In case of
Extended Partition, displays Physical Partition number of Parent Partition.
Displays the name of the Partition.
Displays the Power Status of the Partition.
On
Standby
The status of the partition progress is displayed.
Power Off: The partition power is off.
Power On In Progress: Partition power on is in process.
Reset: The status of the partition from the beginning of reset till the
completion of the operating system boot.
EFI: The UEFI menu screen is displayed.
Boot: Operating system is being booted.
Operating system Running: Operating system running state
Operating system Shutdown: Operating system shutting down.
Panic: Panic (Only in RHEL)
Power Off In Progress: Partition power off is in process.
Fatal: Stopped.
Dumping: The dumping is being output.
Halt: Halting.
Extended Partitioning Running: The firmware of Extended Partitioning is
operating.
Remarks
When SVAS (Server View Agentless Service) is not installed to partition,
the display is not switched over in 'Operating system Running' even if
Operating system is working.
Moreover, for 'Operating system shutdown', 'Panic' commanded by
SVAS if SVAS is not installed, there is no display.
SVAS : Specifies the piece of software running on the OS in managed
nodes to help BMC with management. Unless SVAgent, it does not
provide management interface to the outside.
The operation at kdump by Linux OS is as follows.
RHEL : It changes to "Panic" and "Dumping". (Only when "FJSVfefpcl"
package is installed.)
SUSE : It does not change "Panic" and "Dumping".
When REMCS Option is installed on Partition of RHEL, "Panic" is
displayed. It is not displayed in Windows.