Brother PR600II Service Manual page 103

Hide thumbs Also See for PR600II:
Table of Contents

Advertisement

Main unit
5
Inverter D6 attachment
1. Position the inverter PCB collars 1 on the PCB attachment plate, set
inverter D6 2, and then secure them with 2 screws 1.
2. Attach the inverter lead wire 3 and the LCD lead wire 4 to inverter D6
2.
1
6
Panel PCB assembly attachment
1. Attach the panel PCB assembly 1 with the 7 screws 1.
2. Connect the inverter lead wire 2 and the SW PCB assembly lead wire 3
to the panel PCB assembly 1.
3. Insert the FFC 4 through the ferrite core 5.
4. Attach the FFC 4 to the connector on the panel PCB assembly 1.
*Key point
• Unlock the connector, insert the FFC, and then lock the
connector.
5. Attach the FFC 6 to the connector on the panel PCB assembly 1.
*Key point
• Unlock the connector, insert the FFC, and then lock the
connector.
1
Operation panel
Screw, Pan (S/P washer)
0.49 – 0.69 N-m
M3X10DA
Screw, Pan (S/P washer)
0.49 – 0.69 N-m
M3X6
Torque
3
1
1
Torque
3
1
2
1
4
1
1
6
2
4
5
3 - 5