SW102 No.5–No.8 Scan effective image area main scan
right edge image loss (OC)
Used to set image loss in scan image area.
Image loss on the right edge in OC main scan direction can be
adjusted. When the set value is increased, image loss is increased.
Setting is made in binary input in the increment of 24 dots.
Default: 96 dots
SW103 No.1–No.4 Scan effective image area sub scan
lead edge image loss (OC)
Used to set image loss in scan image area.
Image loss on the lead edge in OC sub scan direction can be
adjusted. When the set value is increased, image loss is increased.
Setting is made in binary input in the increment of 16 lines.
Default: 96 lines
SW103 No.5–No.8 Scan effective image area sub scan
rear edge image loss (OC)
Used to set image loss in scan image area.
Image loss on the rear edge in OC sub scan direction can be
adjusted. When the set value is increased, image loss is increased.
Setting is made in binary input in the increment of 16 lines.
Default: 144 lines
SW104 No.1–No.4 Scan effective image area main scan
left edge image loss (RSPF back surface)
Used to set image loss in scan image area.
Image loss in RSPF back surface main scan direction can be
adjusted. When the set value is increased, image loss is increased.
Setting is made in binary input in the increment of 24 dots.
Default: 96 dots
SW104 No.5–No.8 Scan effective image area main scan
right edge image loss (RSPF back surface)
Used to set image loss in scan image area.
Image loss on the right edge in RSPF back surface main scan direc-
tion can be adjusted. When the set value is increased, image loss is
increased.
Setting is made in binary input in the increment of 24 dots.
Default: 96 dots
SW105 No.1 Scan magnification ratio adjustment
(OC main scan) flag
Used to set the main scan magnification ratio in OC scan.
Bit 1 indicates plus or minus of the magnification ratio.
Default: 0 (+)
SW105 No.2–No.8 Scan magnification ratio adjustment
(OC main scan)
Used to set the main scan magnification ratio in OC scan.
By binary input, setting can be made in the range of 0 – ±12.7% in
0.1% increments.
Default: 0%
SW106 No.1 Scan magnification ratio adjustment
(OC sub scan) flag
Used to set the sub scan magnification ratio in OC scan.
Bit 1 indicates plus or minus of the magnification ratio.
Default: 0 (+)
SW106 No.2–No.8 Scan magnification ratio adjustment
(OC sub scan)
Used to set the sub scan magnification ratio in OC scan.
By binary input, setting can be made in the range of 0 – ±12.7% in
0.1% increments.
Default: 0%
AL-2020/2035/2040/2050/2060 FAX SOFT SWITCH 12 - 31
SW107 No.1 Scan magnification ratio adjustment
(RSPF back surface main scan) flag
Used to set the main scan magnification ratio in RSPF back surface
scan.
Bit 1 indicates plus or minus of the magnification ratio.
Default: 0 (+)
SW107 No.2–No.8 Scan magnification ratio adjustment
(RSPF back surface main scan)
Used to set the main scan magnification ratio in RSPF back surface
scan.
By binary input, setting can be made in the range of 0 – ±12.7% in
0.1% increments.
Default: 0%
SW108 No.1 Scan magnification ratio adjustment
(RSPF back surface sub scan) flag
Used to set the sub scan magnification ratio in RSPF back surface
scan.
Bit 1 indicates plus or minus of the magnification ratio.
Default: 0 (+)
SW108 No.2–No.8 Scan magnification ratio adjustment
(RSPF back surface sub scan)
Used to set the sub scan magnification ratio in RSPF back surface
scan.
By binary input, setting can be made in the range of 0 – ±12.7% in
0.1% increments.
Default: 0%
SW109 No.1 Print magnification ratio adjustment
(Main scan back surface) flag
Used to set the main scan magnification ratio in back surface print.
Bit 1 indicates plus or minus of the magnification ratio.
Default: 0 (+)
SW109 No.2–No.8 Print magnification ratio adjustment
(Main scan back surface)
Used to set the main scan magnification ratio in back surface print.
By binary input, setting can be made in the range of 0 – ±12.7% in
0.1% increments.
Default: 0%
SW110 No.1 Print magnification ratio adjustment
(Sub scan back surface) flag
Used to set the sub scan magnification ratio in back surface print.
Bit 1 indicates plus or minus of the magnification ratio.
Default: 0 (+)
SW110 No.2–No.8 Print magnification ratio adjustment
(Sub scan back surface)
Used to set the sub scan magnification ratio in back surface print.
By binary input, setting can be made in the range of 0 – ±12.7% in
0.1% increments.
Default: 0%