Sharp AL-2020 Service Manual page 96

Digital multifunctional system
Hide thumbs Also See for AL-2020:
Table of Contents

Advertisement

Main
Sub
Contents
code
code
7
08
Shift to copy with the
warm-up display
8
01
Developing bias
02
Main charger (Grid high)
03
Grid voltage (Low)
06
Transfer charger
9
01
Duplex motor normal
rotation operation check
02
Duplex motor reverse
operation check
[Function]
Enter the simulation code, and warm-up is started and warm-up time is counted for every sec-
ond from 0 and displayed.
When [Clear All] key is pressed during counting up, "0" is displayed on the display and counting
is stopped. However, warm-up is continued.
After completion of warm-up, counting is terminated. (The aging function is removed from simu-
lation 7-01.)
[Operation] (AL-2050/2060)
1) Initial display
07-08 W-UP C-MODE
[Function]
When [OK]/[START] key is pressed, the developing bias signal is turned ON for 30sec.
When, however, an actual output value is measured, use simulation 25-01.
After completion of this process, the machine goes into the sub code entry standby mode.
[Operation] (AL-2050/2060)
1) Initial display
08-01 DVLP BIAS SET.
EXECUTING...
[Function]
When [OK]/[START] key is pressed, the main charger is outputted for 30sec in the grid voltage
HIGH move.
After completion of this process, the machine goes into the sub code entry standby mode.
[Operation] (AL-2050/2060)
1) Initial display
08-02 MHV(H) SET.
EXECUTING...
[Function]
When [OK]/[START] key is pressed, the main charger is outputted for 30sec in the grid voltage
LOW move.
After completion of this process, the machine goes into the sub code entry standby mode.
[Operation] (AL-2050/2060)
1) Initial display
08-03 MHV(L) SET.
EXECUTING...
[Function]
When [OK]/[START] key is pressed, the transfer charger is outputted for 30sec.
After completion of this process, the machine goes into the sub code entry standby mode.
[Operation] (AL-2050/2060)
1) Initial display
08-06 THV SET.
EXECUTING...
[Function]
Use the duplex motor Bios to drive the duplex motor in the normal direction (paper exit direc-
tion) for 30sec.
After completion of this process, the machine goes into the sub code entry standby mode.
[Operation] (AL-2050/2060)
1) Initial display
09-01 DPLX ROT.
EXECUTING...
[Function]
Use the duplex motor Bios to drive the duplex motor in the reverse direction for 30sec.
After completion of this process, the machine goes into the sub code entry standby mode.
[Operation] (AL-2050/2060)
1) Initial display
09-02 DPLX ROT.REV.
EXECUTING...
AL-2020/2035/2040/2050/2060 SIMULATION, TROUBLE CODES 10 - 6
Details of function/operation
2) After 10sec
07-08 W-UP C-MODE
0