code
code
5
03
Copy lamp ON
6
01
Paper feed solenoid ON
02
Resist solenoid ON
7
01
Warm-up display and aging
with jam
06
Intermittent aging
[Function]
When [OK]/[START] key is pressed, the copy lamp turns ON for 5sec.
[Operation] (AL-2050/2060)
1) Initial display
05-03 C-LAMP CHK
EXECUTING...
[Function]
When [OK]/[START] key is pressed, the selected paper feed solenoid repeats ON for 500ms
and OF for 500ms 20times.
When tray select key (or [Numeric] key or [
paper feed solenoid setting is switched.
Code number
0
1
2
[Operation] (AL-2050/2060)
1) Initial display
06-01 PSOL CHK
0:CPFS1
[Function]
When [OK]/[START] key is pressed, the resist solenoid repeats ON for 500ms and OFF for
500ms 20 times.
[Operation] (AL-2050/2060)
1) Initial display
06-02 RES.R SOL CHK
EXECUTING...
[Function]
Copying is repeated to make the set quantity of copies.
When the simulation is executed, warm-up is started and warm-up time is added for every sec-
ond from 0 and displayed.
When warm-up is completed, addition is stopped. When [Clear All] key is pressed, the ready
lamp lights up.
After that, enter the copy quantity with [ ] [ ] key (or [Numeric] key for the AL-2050/2060) and
press [OK]/[START] key to repeat copying of the set quantity (interval 0sec).
To cancel the simulation, turn off the power or execute a simulation which causes hardware
reset.
[Operation] (AL-2050/2060)
1) Initial display
07-01 W-UP/AGING
[Function]
Copying is repeated to make the set quantity of copies.
When the simulation is executed, warm-up is performed and the ready lamp is lighted.
Enter the copy quantity with the [ ] [ ] key (or [Numeric] key for the AL-2050/2060) and press
[OK]/[START] key, and copying is executed to make the set quantity of copies, and the ready
state is kept for 3sec, and copying is executed again to make the set quantity of copies. These
operations are repeated.
To cancel the simulation, turn off the power or execute a simulation which executes hardware
reset.
[Operation] (AL-2050/2060)
1) Initial display (Basic display of copy)
READY TO COPY
100%
A4
AL-2020/2035/2040/2050/2060 SIMULATION, TROUBLE CODES 10 - 5
Details of function/operation
] [
Setting
CPFS1
CPFS2
Operation is possible only when No. 2 cassette is installed.
MPFS
2) [Numeric] key or [
06-01 PSOL CHK
1:CPFS2
2) [Numeric] key or [
06-01 PSOL CHK
2:MPFS
2) After 10sec
07-01 W-UP/AGING
0
0
] key for the AL-2050/2060) is pressed, the
Remark
] key
3) [OK]/[START] key
06-01 PSOL CHK
EXECUTING...
] key
4) Returns to the initial display.