SELECTING A SITE

Read the following precautions before selecting a suitable site for your server. The following describes installation of
the server and connections to the server.
Observe the following instructions to use the server safely. Failure to follow these instructions
may cause a fire, personal injury, or property damage. See pages 1-3 to 1-8 for details.
Never attempt to lift the server with three or less persons.
Do not install the server in any place other than specified.
The following figure illustrates a site suitable for installing the server.
Room that satisfies the following
conditions for operation: *
Temperature: 10 to 35ºC
Humidity: 20 to 80% (no
condensation)
Place having available
space of 150 mm or more in
front and rear of the server.
100 to 120 Vac/200 to
240 Vac parallel
bi-polar wall power
outlet with the ground
li
Wall outlet to connect the
supplied power cord.
Place having a space enough to fully
open the front door (The front door
extrudes about 35 mm from the left
side of the server when fully opened.)
When you have selected a server site, hold the server by its bottom with at least four persons and carry it to the site,
then place it slowly and gently.
IMPORTANT:
may be disengaged and damage the server.
Do not hold the server by its front door to lift the server. The front door
CAUTION
Install the server on the
floor or rigid, flat desk.
* It is recommended that the server should be used in a room where
temperature is in the range between 15 to 25ºC.
Close enough to
connect the mouse
and the display.
Clean and tidy room