NEC 140He User Manual page 94

140he
Table of Contents

Advertisement

4-22
Option
Parameter
Boot
[Retry 3 Times]
Monitoring
Retry Service Boot
Policy
Always Retest
Thermal
Disabled
Sensor
[Enabled]
BMC IRQ
Disabled
[IRQ 11]
Post Error
Disabled
Pause
[Enabled]
AC-LINK
Stay Off
[Last State]
Power On
Power ON
[0] - 255
Delay Time
FRU LED
Disabled
Feature
[Enabled]
Clear FRU
[No]
LED
Yes
Platform
Disabled
Event
[Enabled]
Filtering
The table below shows the operation when the AC power to the server is turn off once and then on again, depending on
the setting of "AC-LINK."
System status before AC power off
Operating
Aborting (DC power being off also)
Forced shutdown
* Press the power switch continuously at least four seconds. This forcibly turns off the power.
IMPORTANT:
from UPS when the server is connected to UPS.
Description
Appears when the boot monitoring feature is enabled. This
item indicates the processing at the occurrence of timeout
during boot monitoring.
If [Retry 3 times] is selected, the system is reset after the
occurrence of timeout and operating system boot is retried up
to three times. The failure in the third boot causes the boot to
be tried from the service partition.
If [Retry Service Boot] is selected, the system is reset after
the occurrence of timeout and operating system boot is
retried up to three times. Then the boot is tried from the
service partition for three times.
If [Always Reset] is selected, the system is reset after the
occurrence of timeout and operating system boot is retried
repeatedly.
Indicates whether the temperature sensor monitoring function
is enabled or disabled.
Indicates the IRQ of the BMC interrupt.
Indicates whether POST is aborted once at the end of POST
if an error occurs during the execution of POST.
Indicates the AC-LINK function. Shows the state of the power
of the server.
Sets the power on delay time when "Power On" or "Last
State" is specified for AC LINK.
Select "Enabled" to turn on the error lamp to identify the
location if the system detects a failure.
Select "Yes" to turn off the FRU LED. When the faulty
component is replaced, turn off the FRU LED.
Enables or disables the Platform Event Filtering feature of the
baseboard management controller (BMC).
Setting of AC-LINK
Stay Off
Off
Off
Off
Set this item to "Power on" in order to link the AC power source supplied
Last State
Power On
On
On
Off
On
Off
On
Your Setting
[ ]: Factory-set