Toshiba TDP-SW20 Service Manual page 33

Hide thumbs Also See for TDP-SW20:
Table of Contents

Advertisement

8) Altitude
Press [On/Standby] and [Up] buttons simultaneously. The following menu appears.
Notes: For it disappears, press [Return] button.
For it initialize the values, press [Setup] button.
Select proper value by pressing the [Left] or [Right] button.
Factory setting is 0.
The value 1 is more than
The value 2 is more than 1,000m (3,281ft) and under 1,500m (4,921ft).
The value 3 is more than 1,500m (4,921ft) and under 2,000m (6,562ft).
The value 4 is more than 2,000m (6,562ft) and under 2,500m (8,202ft).
The value 5 is more than 2,500m (8,202ft) and under 3,000m (9,843ft).
The value 6 is more than 3,000m (9,843ft).
For example
In case of 2,700m altitude, set the value to 5.
Press [Return] button.
9) Save data to EEPROM
Press the buttons,
[Up], [Down], [Left] and [Right] simultaneously.
When these buttons are accepted, all LED's light orange.
500m (1,640ft) and under 1,000m (3,281ft).