ABB ACSM1 Manual page 58

Motion control system
Hide thumbs Also See for ACSM1:
Table of Contents

Advertisement

58
The brake on/off is controlled via signal
supervision is selected by parameter
The brake control hardware and wirings need to be done by the user.
• Brake on/off control through selected relay/digital output.
• Brake supervision through selected digital input.
• Emergency brake switch in the brake control circuit.
• Brake on/off control through relay output (ie, parameter
3.15 BRAKE
• Brake supervision through digital input DI5 (ie, parameter
P.02.01.04 =
Drive control and features
COMMAND).
2.01 DI STATUS
bit 4)
Brake control
hardware
230 VAC
Emergency
brake
M
Mechanical brake
Motor
3.15 BRAKE
COMMAND. The source for the brake
35.02 BRAKE
ACKNOWL.
12.12 RO1 OUT PTR
35.02 BRAKE ACKNOWL
JCU unit
X2
1
RO1
2
RO1
3
RO1
X3
11 DI5
13 +24 V
is set to P.03.15 =
is set to

Hide quick links: