Function Number
Symbol
Positive
Negative
logic
logic
118
119
STPC
120
121
LLS
122
123
KEB
124
125
TVS
126
127
TVSD
128
129
LTA
130
131
POT
132
133
FMOD
134
135
FL3
136
137
FLC
138
139
FORCE
140
141
FIRE
142
143
UTA
144
145
PIDF
150
151
PTCA
152
153
STO
154
155
DISK
156
157
LI1
158
159
LI2
160
161
LTAF
162
163
NSA
164
165
LLD2
166
167
DACC
168
169
DDEC
170
171
DRUN
172
173
DDC
174
175
HSTOP
176
177
SRVLR
Function
Stop positioning comple-
ON: Stop position completion
tion
During sleep
ON: During sleep
During synchronized Acc/
ON: During synchronized acceleration/deceleration
Dec
During traverse operation ON: During traverse operation
During traverse Dec
ON: During traverse deceleration
ON: Any one of cooling fan, control board capacitor, or power
Parts replacement alarm
circuit capacitor reaches parts replacement time
ON: Torque current is 70% of <F616: Overtorque detection
Overtorque (OT) pre-
level during power running> setting value or more
alarm
OFF: Torque current is under <F616> x 70%-<F619: Over-
torque detection hysteresis>
Frequency command 1/
ON: <F207: Frequency command select 2> enabled
Frequency command 2
OFF: <FMOd: Frequency command select 1> enabled
Failure signal 3
ON: During trip (except Emergency off)
ON: Run command or panel run, OFF: Other than those at
Hand/Auto
left
During forced run
ON: During forced run
During fire speed run
ON: During fire speed run
Undertorque alarm
ON: Undertorque alarm level or more
ON: Frequency commanded by <F389: PID1 set value select >
PID1,2 frequency
and <F360: PID1 feedback input select > are within ± <F374:
command agreement
PID1 set value agreement detection band>
ON: PTC thermal input value is 60% of <F646: PTC detection
PTC input pre-alarm
resistance> or more
During Safe Torque Off
ON: Open between [STOA]-[STOB]-[PLC]
(STO)
OFF: Short circuit between [STOA]-[STOB]-[PLC]
Analog input disconnect-
ON: The input value of terminal [II] is <F633: II analog input
ing alarm
disconnection detection level> or less
Terminal F ON/OFF
ON: Terminal [F] is ON, OFF: Terminal [F] is OFF
Terminal R ON/OFF
ON: Terminal [R] is ON, OFF: Terminal [R] is OFF
Cooling fan replacement
ON: Cooling fan reaches parts replacement time
alarm
ON: Number of starting is <F648: Number of starting alarm>
Number of starting alarm
or more
Light load detection 2
ON: Light load detection (compatible with old model)
During Acc
ON: During acceleration
During Dec
ON: During deceleration
During constant speed
ON: During constant speed run
run
During DC braking
ON: During DC braking
During hit and stop
ON: During hit and stop
During run including
ON: During run including servo lock
servo lock
11-63
E6582062
Action
11. Table of parameters
Reference
[7. 2. 2]
1
[6. 30. 17]
[7. 2. 2]
3
[7. 2. 2]
[6. 31]
[7. 2. 2]
[7. 2. 2]
9
[6. 30. 19]
[7. 2. 2]
10
[7. 2. 2]
11
[6. 30. 17]
[7. 2. 2]
[6. 30. 21]
[7. 2. 2]
[7. 2. 2]
[7. 2. 2]