Input Signal Selection - Toshiba Tosvert VF-S15 Instruction Manual

Industrial inverter
Hide thumbs Also See for Tosvert VF-S15:
Table of Contents

Advertisement

6.6

Input signal selection

6.6.1
Priority selection (Both F and R are ON)
f105 : Priority selection (Both F and R are ON)
 Function
This parameter allows you to select the direction in which the motor runs when a forward run (F)
command and a reverse run (R) command are entered simultaneously.
1) Reverse
2) Deceleration stop
[Parameter setting]
Title
Priority selection
f105
(Both F and R are ON)
(1) [f105 = 0 (Reverse)]: If an F command and an R command are entered simultaneously,
Output frequency [Hz]
Setting frequency
Setting frequency
Forward run command
Reverse run command
Function
the motor will run in the reverse direction.
0
F-29
Adjustment range
0: Reverse
1: Deceleration stop
E6582175
Default setting
1
6
Forward run
Time [s]
Reverse run
ON
OFF
ON
OFF