■ Parameters changed default setting values
Table 1 : Parameter list changed default setting values at software V120 or later version
Com.
Title
No
vb
0016
f172
0172
f402
0402
f415
0415
f416
0416
f417
0417
f456
0456
f457
0457
f458
0458
f459
0459
*1: Default setting values are different depending on the inverter ratings. (Refer to Table 3.)
*2: Refer to section 11.2 to 11.5.
■ Default setting, region setting
Regarding the change of the parameter default setting values described on Table 1, the several functions described below are
changed from V120 or later version.
Item
50Hz default setting
Function is not changed.
(typ=1)
60Hz default setting
Function is not changed.
(typ=2)
Default setting 1
Parameters on Table 1 are initialized to the
(typ=3)
values described on Table 4.
Parameters on Table 1 are initialized to the
Default setting 2
values described on Table 4.
(typ=13)
(Region setting is required in advance)
Region setting
Parameters on Table 1 are initialized to the
values described on Table 4.
(set)
(f456 and f457 do not exist on V110 or earlier version inverter.)
17
Function
Torque boost value 1
Torque boost value 2
Automatic torque boost value
Motor rated current
Motor no-load current
Motor rated speed
Motor specific constant 12
Motor specific constant 13
Motor specific constant 2
Load inertia moment ratio
Table 2 : Function changed at V120 or later version inverter
Before (V116 or earlier version)
f417(Motor rated speed): 1410(min
f417(Motor rated speed): 1710(min
Minimum
Adjustment
Unit
setting unit
range
Panel/Com.
%
0.1 / 0.1
0.0 - 30.0
%
0.1 / 0.1
0.0 - 30.0
%
0.1 / 0.1
0.1 - 30.0
A
0.01 / 0.01
0.10 - 100.00
%
1 / 1
10 - 90
-1
min
1 / 1
100 - 64000
-
1 / 1
20 - 150
-
1 / 1
5 - 75
-
1 / 1
0 - 101
Times
0.1 / 0.1
0.1 - 100.0
After (V120 or later version)
-1
) is set. It is NOT dependent on the inverter ratings.
-1
) is set. It is NOT dependent on the inverter ratings.
Parameters on Table1 are initialized to the
values described on Table 3.
Parameters on Table 1 are initialized to the
values described on Table 3.
(Region setting is required in advance)
Parameters on Table 1 are initialized to the
values described on Table 3.
S-3
E6582175
Default
Reference
setting
*2
*1
6.4
*1
6.8.1
*1
6.25
*1
*1
*1
120
-
50
-
101
-
1.5
6.25
Reference
4.3.2
4.4
11.5