Toshiba Tosvert VF-S15 Instruction Manual page 310

Industrial inverter
Hide thumbs Also See for Tosvert VF-S15:
Table of Contents

Advertisement

 Operation mode parameters
Communication
Title
Function
No.
0300
PWM carrier

frequency
0301
Auto-restart

control selection
0302
Regenerative

power ride-
through control
(Deceleration
stop)
0303
Retry selection

(number of times)
0304
Dynamic braking

selection
0305
Overvoltage limit

operation
(Deceleration stop
mode selection)
0306
Factory specific

coefficient 3L
0307
Supply voltage

correction
(output voltage
limitation)
0308
Dynamic braking

resistance
0309
Dynamic braking

resistor capacity
0310
Factory specific

coefficient 3A
0311
Reverse-run

prohibition
0312
Random mode

0314
Factory specific

coefficient 3B
*1: Default setting values vary depending on the setup menu setting. Refer to section 11.5.
*2: Default setting values vary depending on the capacity. Refer to section 11.4.
*3: Factory specific coefficient parameters are manufacturer setting parameters. Do not change the value of these parameters.
Minimum
setting unit
Unit
Adjustment range
Panel/Commun
ication
kHz
0.1/0.1
2.0 -16.0
-
-
0: Disabled
1: At auto-restart after momentary
stop
2: At ST terminal off and on
3: 1+2
4: At start-up
-
-
0: Disabled
1: Regenerative power ride-through
control
2: Deceleration stop during power
failure
3: Synchronized acceleration /
deceleration (signal)
4: Synchronized acceleration /
deceleration (signal + power failure)
Times
1/1
0: Disabled
1-10
-
-
0: Disabled
1: Enabled, Resistor overload
protection enabled
2: Enabled
3: Enabled, Resistor overload
protection enabled
(At ST terminal on)
4: Enabled (At ST terminal on)
-
-
0: Enabled
1: Disabled
2: Enabled (Quick deceleration
control)
3: Enabled (Dynamic quick
deceleration control)
-
-
-
-
-
0: Supply voltage uncorrected,
output voltage limited
1: Supply voltage corrected,
output voltage limited
2: Supply voltage uncorrected,
output voltage unlimited
3: Supply voltage corrected,
output voltage unlimited
Ω
0.1/0.1
1.0-1000
kW
0.01/0.01
0.01-30.00
-
-
-
-
-
0: Forward/reverse run permitted
1: Reverse run prohibited
2: Forward run prohibited
-
-
0: Disabled
1: Random mode 1
2: Random mode 2
3: Random mode 3
-
-
-
K-11
E6582175
Default
User
Reference
setting
setting
12.0
6.18
0
5.9
0
6.19.2
0
6.19.3
0
6.19.4
2
6.19.5
-
* 3
*1
6.19.6
*2
6.19.4
*2
-
* 3
0
6.19.7
0
6.18
-
* 3
11