■Applicable devices
Operand
Bit
X, Y, M, L,
J\
SM, F, B, SB,
FX, FY
(s1)
(s2)
(s3)
(s4)
(s5)
(d1)
(d2)
■Update target field name
Operand: (s3)
Device
Item
+0
Number of fields
+1 to +
Field name
*1 "1" to "16" for a programmable controller CPU with firmware version earlier than "28"
■Updated data
Operand: (s4)
Device
Item
+0
Data size
+1
Not used
+2 to +
Set value
The following figure shows the setting format of (s4). Set the value corresponding to each field in (s3). The data size of each
set value follows the size of the data type of each field. (Page 956 DBINSERT(P))
b15
∙∙∙
(s4)
(s4)+1
(s4)+2
1
n
(s4)+
Word
T, ST, C, D, W,
U\G, J\,
SD, SW, FD, R,
U3E\(H)G
ZR, RD
Description
Specify the number of fields to be updated.
Specify the name of each field. Specify field names, each fixed to 32 characters, by
the number of fields with Unicode character strings. For the name less than 32
characters, the character string should be right-justified and filled with 0000H to
become a 32-character string.
The last address  in (s3) varies according to the number of fields.
=32n (n: number of fields)
Description
Set the data size of the field to be updated.
Set the updated data.
b0
Set the data size per record.
A value set in the 1st field
A value set in the 'n'th field
Double word Indirect
specification
Z
LT, LST,
LZ
LC
Setting range
1 to 128
Setting range
Depends on the
data type
Data for one
record
7 APPLICATION INSTRUCTIONS
7.21 Database Access Instructions
Constant
Others
K, H E
$
Set by
*1
User
User
7
Set by
User
User
963